Online courses for the ham radio license exams. Questions?  Email Ham Test Online at support@hamtestonline.com

Warning: Nightly processing will begin in 6.3 minutes.  Expect processing interruptions.

 

General Class Exam Question Pool

effective 7/01/2011 thru 6/30/2015

Show:
    Unseen questions
    Weak questions
    Review questions
    Learned questions
    Incorrect answer choices  
   

G0B-2011: Safety in the ham shack: electrical shock and treatment, safety grounding, fusing, interlocks, wiring, antenna and tower safety

G0B01-2011: Which wire or wires in a four-conductor line cord should be attached to fuses or circuit breakers in a device operated from a 240-VAC single-phase source?

Only the hot wires

Only the neutral wire

Only the ground wire

All wires



G0B02-2011: What is the minimum wire size that may be safely used for a circuit that draws up to 20 amperes of continuous current?

AWG number 12

AWG number 20

AWG number 16

AWG number 8



G0B03-2011: Which size of fuse or circuit breaker would be appropriate to use with a circuit that uses AWG number 14 wiring?

15 amperes

100 amperes

60 amperes

30 amperes



G0B04-2011: Which of the following is a primary reason for not placing a gasoline-fueled generator inside an occupied area?

Danger of carbon monoxide poisoning

Danger of engine over torque

Lack of oxygen for adequate combustion

Lack of nitrogen for adequate combustion



G0B05-2011: Which of the following conditions will cause a Ground Fault Circuit Interrupter (GFCI) to disconnect the 120 or 240 Volt AC line power to a device?

Current flowing from one or more of the hot wires directly to ground

Current flowing from one or more of the hot wires to the neutral wire

Over-voltage on the hot wire

All of these choices are correct



G0B06-2011: Why must the metal enclosure of every item of station equipment be grounded?

It ensures that hazardous voltages cannot appear on the chassis

It prevents blowing of fuses in case of an internal short circuit

It prevents signal overload

It ensures that the neutral wire is grounded



G0B07-2011: Which of the following should be observed for safety when climbing on a tower using a safety belt or harness?

Always attach the belt safety hook to the belt D-ring with the hook opening away from the tower

Never lean back and rely on the belt alone to support your weight

Ensure that all heavy tools are securely fastened to the belt D-ring

Make sure that your belt is grounded at all times



G0B08-2011: What should be done by any person preparing to climb a tower that supports electrically powered devices?

Make sure all circuits that supply power to the tower are locked out and tagged

Notify the electric company that a person will be working on the tower

Unground the base of the tower

All of these choices are correct



G0B09-2011: Why should soldered joints not be used with the wires that connect the base of a tower to a system of ground rods?

A soldered joint will likely be destroyed by the heat of a lightning strike

The resistance of solder is too high

Solder flux will prevent a low conductivity connection

Solder has too high a dielectric constant to provide adequate lightning protection



G0B10-2011: Which of the following is a danger from lead-tin solder?

Lead can contaminate food if hands are not washed carefully after handling

High voltages can cause lead-tin solder to disintegrate suddenly

Tin in the solder can “cold flow” causing shorts in the circuit

RF energy can convert the lead into a poisonous gas



G0B11-2011: Which of the following is good engineering practice for lightning protection grounds?

They must be bonded together with all other grounds

They must be bonded to all buried water and gas lines

Bends in ground wires must be made as close as possible to a right angle

Lightning grounds must be connected to all ungrounded wiring



G0B12-2011: What is the purpose of a transmitter power supply interlock?

To ensure that dangerous voltages are removed if the cabinet is opened

To prevent unauthorized access to a transmitter

To guarantee that you cannot accidentally transmit out of band

To shut off the transmitter if too much current is drawn



G0B13-2011: What must you do when powering your house from an emergency generator?

Disconnect the incoming utility power feed

Insure that the generator is not grounded

Insure that all lightning grounds are disconnected

All of these choices are correct



G0B14-2011: Which of the following is covered by the National Electrical Code?

Electrical safety inside the ham shack

Acceptable bandwidth limits

Acceptable modulation limits

RF exposure limits of the human body



G0B15-2011: Which of the following is true of an emergency generator installation?

The generator should be located in a well ventilated area

The generator should be insulated from ground

Fuel should be stored near the generator for rapid refueling in case of an emergency

All of these choices are correct



G0B16-2011: When might a lead acid storage battery give off explosive hydrogen gas?

When being charged

When stored for long periods of time

When being discharged

When not placed on a level surface





Color key:
● = Unseen
● = Weak
● = Review
● = Learned
● = Incorrect answer
Previous group:
G0A-2011: RF safety principles, rules and guidelines; routine station evaluation
Back to index:
General Class Exam Question Pool
 
Home     What is ham radio?     Which exam to take?     Study tips     Where to take the exam?     Frequently Asked Questions (FAQ)     How to     How much math?     Trouble with practice exams     Feedback     Prices     Free Extra course for active volunteer examiners     Refund policy     Terms and conditions     Bumper sticker     Advertise with us     The Ham band     Rate us     Question pools     Course structure     Survivalists     Documents     facebook     Google+     Contact us     May Day Ham Radio!     Christina's story     TestOnline     Links
A TestOnline website.  Copyright © 2001-2013, HamTestOnline.  All rights reserved.